Научная статья на тему 'Development of mechanical test procedure for the fuel bellows tanks'

Development of mechanical test procedure for the fuel bellows tanks Текст научной статьи по специальности «Медицинские технологии»

CC BY
112
71
i Надоели баннеры? Вы всегда можете отключить рекламу.
Ключевые слова
SPACECRAFT / TANK / STORAGE AND FEED UNIT / MECHANICAL TESTS / RESONANCE

Аннотация научной статьи по медицинским технологиям, автор научной работы — Ermoshkin Yu M., Orlov S. A., Usanov A. Yu

The mechanical qualification and acceptance test requirements are considered for the fuel bellows tanks. Some procedural mistakes taking place during these tests are described.

i Надоели баннеры? Вы всегда можете отключить рекламу.
iНе можете найти то, что вам нужно? Попробуйте сервис подбора литературы.
i Надоели баннеры? Вы всегда можете отключить рекламу.

Текст научной работы на тему «Development of mechanical test procedure for the fuel bellows tanks»

Bibliography

1. Dmitrikov, V F. Highly effective shapers ofharmonious fluctuations/N. B. Petjashin, M. A. Sivers. M., 1988.192 p. (inRussian)

2. Khmelnitskiy, E. P. Work of the lamp generator on the upset contour / E. P. Khmelnitskiy. M., 1962. 109 p. (in Russian)

3. Artym, A. D. Amplifier of classes D and key generators in a radio communication and broadcasting / A. D. Artym. M., 1980. -209 p. (inRussian)

© Mikheenko A. M., Abramov S. S., Rezan 1.1., 2009

Yu. M. Ermoshkin, S. A. Orlov JSC “AcademicianM. F. Reshetnev “Information Satellite Systems”, Russia, Zheleznogorsk

A. Yu. Usanov Experimental DesignBureau “Fakel”, Russia, Kaliningrad

DEVELOPMENT OF MECHANICAL TEST PROCEDURE FOR THE FUEL BELLOWS TANKS

The mechanical qualification and acceptance test requirements are considered for the fuel bellows tanks. Some procedural mistakes taking place during these tests are described.

Keywords: spacecraft, tank, storage and feed unit, mechanical tests, resonance.

For decades the fuel storage/feed units based on the bellows tanks are successfully used in the monopropellant propulsions ofthe domestic spacecrafts (SCs). Inorderto use the fuel storage units for new generation SCs (i. e. to be exposed higher mechanical loads) there was a necessity to perform supplemental mechanical tests to prove their durability.

SC hardware ground test plan includes the acceleration, vibration and shock tests [1; 2]. The tests levels are based on the data obtained from hardware operating conditions analysis, equipment mass and its allocation on the SC.

The storage and feed unit (SFU) manufacturer has to procure off-the shelf tanks from other supplier and then has to equip it with supplemental hardware in order to obtain the SFU as an item of SC propulsion.

During the SFU development testing, bellows of two tanks were corrupted (along an external crimp weld) when they were exposed to mechanical environment. This damage occurred directly along the weld, and not in an area around the weld; it was typically if the weld was well done i. e. this damage designated an insufficient quality of the join. It is necessary to note that such welds in the tanks are critical because they influence the strength of the whole assembly; the thickness of weldment isn’t great, while the total length of weld may be hundreds of meters long. However, all the delivered tanks for the integration of the SFUs have passed the acceptance tests at the manufacturer’s site.

In order to analyze the failures of tank bellows and to generate the levels of durability and acceptance tests, supplemental mechanical tests of two SFUs had been conducted. This work is meant to review all the test results and to identify the possible procedural mistakes that have made it impossible to detect manufacturing flaws during the acceptance tests of tanks.

Test Objectives. During the test campaign it was necessary to achieve a set of mutually complementary objectives:

- to detect the rupture sources of tank bellows;

- to develop a technique for determination of low eigenfrequencies of the bellows located inside a tank;

- to estimateaninfluence of testprocedure onthe test data;

- to confirm or exclude an influence of the test hardware (fixture, tools, control system, etc) to the test results;

- to update the durability/acceptance test levels for tank andSFU.

Test equipment and mechanical loads. The following mechanical tests were performed:

- resonance search within a frequency range of 5 Hz to

2.000 Hz with level of0,5g and a scanning rate of 2 octave/min;

- sine vibration within a frequency range of5Hzto2,000 Hz with levels of1to12g;

- random vibration within a frequency range of20Hz to

2.000 Hz with levels of0.02to0.2 g2/Hz;

- quasi-static loads with levels of ±10g;

- shocks with levels of ±40 g.

The test specifications were generated proceeding from the SFU operation conditions at levels of the SC and in compliance with an approach as described in [3; 4]. They have met the requirements as established in[1;2]. The tests were conducted in few phases changing the levels and duration ofloading. The following equipment was used:

- centrifuge C-400;

- shock testbench ST-800;

- vibration shakerLDS V894/440.

Beforehand, the test equipment and test fixture were subjected to approval. The equipment’s low eigenfrequency is about 1,000 Hz. All the test hardware corresponded to the test standards according to the test specification accuracy and provided the mechanical loading of the SFU and was measured with the following tolerances:

- vibration acceleration amplitude: ±10 %;

- vibration acceleration power spectral density: ±6dB;

- vibration frequency: ±2 % within a frequency range of

5 Hzto 2,000 Hz;

- vibration acceleration RMS value: ±4 %;

- shock acceleration: ±15 %;

- linearacceleration: ±10 %.

Description of Tank Design. For the following analysis and identification of the bellows failures let us consider a design of the bellows tank. Figure 1 depicts its schematic diagram. The tank consists of a cylindrical case 1 with spherical bottoms 2. The bellows 3 is welded on the aft of a cylinder 1. Afluoroplastic ring 4 is installed on a free end of the bellows to provide gliding for the bellows on the case 1 along an axis and to restrain sideward shift. Minimum clearance 5 exists betweenthe case andbellows. Agas cavity

6 is formed in the spherical bottom at a side of fluoroplastic ring 4. Bellows are filled with a simulator of fuel (water).

1 2 3 4 5 6 2

To justify a possibility of performing such measurements a groove was made on one of a SFU specimen case in the field of sensor 5Y and an accelerometer was installed on a plane of sensors 5 allocation.

Fig. 1. Schematic diagram of the tank

Estimation of SFU eigenfrequencies. After the first phases of testing it became clear that the shock and quasistatic (linear) loads cannotbe a source of SFU failures, not speaking about the damage of tanks through loads without loss of bellows tightness.

These results are in compliance with the calculated stresses in the elements of tanks and they show that maximal stresses in bellows at the specified loads should be from 8 to 10 times less than the ones allowed. Before testing we also evaluated the low eigenfrequencies for the bellows and tank. The value of low eigenfrequency for the bellows is 8 Hz. Numerical analyses of stresses and eigenfrequencies were performed in accordance with reference [5].

The evaluation of low frequency for the tank case as in [6] gave a value of about 300 Hz. Eigenfrequencies for the SFU reinforcement (the control points are the following: 1,2,

4, 7) are within a range of 150 to 500 Hz (these results were obtained during earlier tests of the SFU). Thus the test fixture, whose eigenfrequencies are above 1,000 Hz, could not impact on strength of low-frequency bellows as well as on the tank and SFU reinforcement responses. This is why the main attention was paid to the analysis of SFU vibration loading and test procedures.

Vibration test procedures and plans. Figure 2 depicts the locations of accelerometers in the tank case for recording the accelerations during the vibration test (the non-labeled points stand for recording the accelerations along three directions). The objective of the first testing phase was to determine the low eigenfrequencies ofbellows.

Since it was impossible to measure the frequency of the fueled bellows inside the air-tight tank under pressure directly, the experimental data about the eigenfrequency ofbellows was gained by a method of indirect measurements.

Fig.2. Diagram of accelerometers allocation on the SFU

During the vibration test of this SFU by the wobbulator method [4] (the scan rate was 0,6 octave/min and level of load was 0.5 g), the accelerometer installed on the bellows and the accelerometers 5Y, 5Ya, 5Z showed a presence of same frequency resonances. So using the indications of the accelerometers 5Y, 5Ya and 5Z we can be judge about the eigenfrequencies of the SFU bellows. This effect can be explained easily: the gap between the bellows and the tank is small (~1 mm), when resonance phenomena arise, the bellows collide with the tank case at a resonant frequency, whichis recordedby the accelerometers installed on the tank case.

The next testing phase was done to determine the lowest eigenfrequency of the fuelled bellows at levels of the SFU. The testing was conducted with the different scan rates of frequency (2 octave/min and 0.5to0.6 octave/min).

Test results. Resonant frequency search tests for the SFU with the fuelled tank conducted at the frequency scan rate of 2 octave/min have shown that no resonant frequencies exceed 17 Hz (ref. fig. 3). Thus, according to the conventional test procedures as described, for example in [7] a vibration test canbe conducted starting from 10 Hz. Such approaches have been carried out at the tank manufacturer’s site during the selective and acceptance tests’ performance.

Fig. 3.Acceleration plot at point 5Ya during resonance search test with scan rate of 2 octave/min

However, as it is shown in figure 4, when decreasing a scanrate downto 0.5...0.6 octave/minwithinafrequency range

of7 to8Hz, aresonanceappears (i.e. increasingavibrational amplitude by2to4 times), which is absent in figure 3.

2

ICfn

^ t 7 * I It)1 Hr

Fig. 4. Acceleration plot at point 5Ya during resonance search test with scan rate of 0.6 octave/min

This phenomenon can be explained the following way: the bellows contain a bulk of fluid, which makes it fairly inertial. At a scan rate of 2 octave/min the resonances don’t have time to develop which is mistaken as the absence of any resonant frequency. However, when decreasing a scan rate to 0.6 octave/min the bulk of fluid inside the tank is capable to develop the oscillations ofbothbellows and fluid in a low frequency range (i. e. resonance).

It should be noted that the vibration tests at the tank manufacturer factory were envisaged in accordance with a step acceleration method for every frequency sub-range from 10 to 2,000 Hz.

Thenthevibrationtests atthe SFU manufacturerfactory were conducted in accordance with the methodology providing smooth change of frequency from the lower boundary of 5 HZ to the upper of 2,000 Hz with a smooth change of accelerationfrom 1gto12g (wobbulatormethod). Also the wideband random vibration tests equivalent to the sine vibration with a power spectrum density level of up to 0.2 g2/Hz were conducted.

Analysis of differences in the SFU and tank test procedures. The differences detected in the test procedures for the tank and SFU have required performing an additional analysis. Conducting the tests from a frequency of 10 Hz eliminated loading of the bellows with maximal strains within a range of resonant frequencies from 7to8 Hz, because the amplitude of displacement was inerasable to a square of frequency [7]. Inaddition, afterpassinganoctavefrequency range with step increasing ofload, the shaker was switched off and it carried out a new load level setting up by the test control system. It had an attenuation effect on the occurring oscillations; when passing the next frequency range the significant expenditure of energy was required to cause the oscillations ofbellows withfluid again.

A validity of this statement is confirmed by the response plot of point 5Ya obtained from the results of SFU random vibration tests and depicted in figures 5 and 6. The lower boundary of frequency range was 20 Hz and the structural response was at noise level when performing the test with the PSD up to0.05 to 0.07 g2/Hz (fig. 5), within a range of up to 20 Hz. When increasing the PSD to0.2 g2/Hz (ref. fig. 6), the power injected into the bellows was sufficient to

increase the low frequency oscillations even within a frequency range which was excluded from test specification (below20Hz).

So itbecame comprehensible thatthe rupture ofbellows might be caused directly by environment vibration within a low frequency range of up to 10 Hz, which impacts on the low quality bellows weld areas.

As vibration within a range of frequency ranges to10 Hz, which is not used for qualification, acceptance and selective tests of the tank at the manufacturing factory, the weld defects are not detected.

Test based on the wobbulator method (where a low boundary of frequency is 5 Hz) applicable at the SFU manufacturing factory have calculated the tougher loading of the bellows; compared with tests based on the method where stepwise accelerationis appliedwithinthe sub-ranges of frequency. So the hidden weld defects are detected the SFU test phase only.

We shall note that the method based on stepwise acceleration had been used during he 1960s and 1970s. Today this method is not recommended to use because the digital control systems are exploited in compliance with ESA and NASA standards [1;2].

Fig. 5.Acceleration plot at point 5Ya during a wideband random vibration test with PSD of up 0.07 g2/Hz

3: ■;

II ✓ set Atz

I©3 3 3 A 3 6 V 3 1$= a S 4 5*?n. ||)3 3

Fig.6. Acceleration plot at point 5Ya during a wideband random vibration test with PSD of up 0.2 g2/Hz

The qualitatively highervibrationtestprocedures allow the detecting ofbellow weld defects. It is necessary to note that no any requirements of existing test specification are formally disturbed at the tank production factory, but the applied acceptance/selective test procedure don’t allow the detection ofbellow weld defects.

At the same time, analysis shows that in ranges of intermediate and high frequencies a wideband random vibration environment is the closest (of physical nature) to

actual mechanical environment as a response of SC structure to acoustic loads during the launch phase for the SFU at level of SC [1; 2; 7; 8]. Wideband randomvibration allows the loading of the SFU within a wide amplitude/frequency range without the damage of high quality fabricated equipment(fig. 6).

From the said above, we can make the following conclusions and recommendations.

The most probable cause of the tank’s bellows destruction during the SFU mechanical tests was the low quality of bellows crimp welds which have not been detected at the tank production factory, combined with overloads at resonant frequency within a low frequency range (5 to 8 HZ).

During the acceptance/selective tests of the tank at the factory for the purpose of detecting hidden bellows weld defects, it is advisable to use the sine vibration test in low frequency range of 5 to 100 Hz (not less then 5 to 20 Hz) based on a wobbulator method with scan rate no higher than

0.5 to 0.6 octave/min.

It is advisable to use a wideband random vibration test with PSD of 0.05 to 0.07 g2/Hz at the SFU factory during acceptance tests; and it is better to use a sine vibration test

within a low frequency range and wideband random vibration test with PSD of up to 0.2 g2/Hz for the qualification tests.

Bibliography

1. Product verification requirements for launch, upper-stage andspacevehicles//MIL-STD-1540D. 1999.15Jan

2. Spaceengineering.Testing//ECSS-E10-03A. 2002.15Febr.

3. VibrationinEngineeringHandbook. Vol. 5. Measuring and Testing / ed. by M. Genkin, Mashinostroenie. M. : Mashinostroenie, 1981. (inRussian)

4. Test Equipment Handbook. Vol. 2. / ed. by V. Kluev. M.: Mashinostroenie, 1982. (inRussian)

5. Sapozhkov, V. Strength and testing of aircraft and helicopterhydraulicspipelines/V. Sapozhkov, G. Lagosjuk. M.: Mashinostroenie, 1973. (inRussian)

6. Kan, S., Structural Analysis of Shells / S. Kan. M. : Mashinostroenie, 1966. (inRussian)

7. Lenk, A. Mechanical testing of devices and apparatus /A. Lenk,Yu. Renitz. M.: Mir, 1976. (inRussian)

8. Gladky, V Strength, vibration and reliability of flying vehicle/V Gladky. M.: Nauka, 1975. (inRussian)

© Ermoshkin Tu.M., OrlovS.A., UsanovA. Yu, 2009

Yu. M. Ermoshkin, V A. Raevsky, V M. Urusov JCS “AcademicianM. F. Reshetnev “Information Satellite Systems”, Russia, Zheleznogorsk

GEO SATELLITE ATTITUDE AND ORBIT CONTROL: FIXED ORBIT CONTROL THRUSTERS

The paper describes the enhanced application ofhigh-economical electro-jetorbitcontrol thrusters forgeostationary satellites; in particular, generation of controlling moments to the benefit of satellite attitude determination and control subsystems in the course of orbit control maneuvers ongoing. The scheme with thrusters fixed on a satellite body is analyzed. Possible orbit control session procedures are proposed on the basis of controlling moments generation. Advantages and disadvantages of the proposed approach are analyzed.

Keywords: spacecraft, propulsion subsystem, orbital control, attitude control, thruster allocation.

iНе можете найти то, что вам нужно? Попробуйте сервис подбора литературы.

The performance of thruster subsystems dramatically influence the geostationary satellite platform characteristics. The mass of thruster units filled can achieve 15...20 % of a satellite mass, the power consumption of electro-jet thruster unit can be up to 4 kW; therefore even minor reduction of the thruster unit mass and the power consumption allows reducing satellite mass and increasing payload capacity. Taking this information into account, we believe it to be important and reasonable to consider issues of optimal development of satellite attitude and orbit control maneuvers using thruster subsystems. Such aspects usually become essential at the initial design stage of a new satellite design. In practice, solutions are mainly subjective, so their detailed examination and formalization is desirable.

There are three known concepts of attitude and orbit control arrangements using thruster units:

- individual thruster units to ensure attitude and orbit control;

- attitude control (creation of controlling moments) ensured by orbit control thrusters fixed on a satellite body;

- attitude control ensured by orbit control thrusters mounted on one- or two-step drives.

Each of these approaches has its advantages and disadvantages. The first approach is a traditional and simple one implemented on a lot of satellites, including satellites developed and manufacturedby JSC ISS (formerNPO-PM) [1]. This approach allows to individually and independently solve the ballistic task of controlling a SC center of gravity position (orbit control task) and a SC angular position (attitude control task).

The second approach promises a certain mass saving due to refusal of separate attitude control thruster unit, though it probably requires more complicated orbit correction maneuver procedures as the orbit correction task shall be accompanied with a task of controlling moments generation to allow ADCS wheel unloading. Such an approach is